Why a gyroscope gives the body's angular velocity directly (the same at every point of a rigid body) while linear velocity depends on where you look (v = v_c + ω × r) and is not measured by an IMU at all.

Loading simulation…

What it demonstrates

Why a gyroscope gives the body's angular velocity directly (the same at every point of a rigid body) while linear velocity depends on where you look (v = v_c + ω × r) and is not measured by an IMU at all.

How it works

A planar rigid body (a robot base seen from above) is driven with a commanded turn rate and forward speed, each following its command with a 0.25 s first-order lag so accelerations stay finite. The body pose is integrated at 240 Hz.

For the base centre and for an IMU mounted at offset r along the body x axis, the code computes the world-frame velocity v = v_c + ω × r and acceleration a = a_c + α × r − ω² r. The accelerometer reading is that acceleration rotated into the body frame (gravity is vertical and does not appear in this horizontal view). The gyro reading is ω.

Adjustable parameters

  • Motion: spin in place, straight, circle
  • Turn rate ω (−3 to 3 rad/s)
  • Forward speed (0–1 m/s)
  • IMU offset r (0–0.4 m)

Known limitations

  • Planar (2-D) motion only; gravity and the vertical axis are left out.
  • The IMU is ideal: no noise, bias or latency.

Equations

ωIMU=ωbody(same everywhere on a rigid body)\omega_{IMU} = \omega_{body} \quad \text{(same everywhere on a rigid body)}
vP=vC+ω×rCPv_P = v_C + \omega \times r_{CP}
aP=aC+α×rCP+ω×(ω×rCP)a_P = a_C + \alpha \times r_{CP} + \omega \times (\omega \times r_{CP})

Core update rule

// lib/sim/ch04-imu.ts — point P at body offset r
const vx = b.vx - b.omega * ry;                       // v = v_c + ω × r
const vy = b.vy + b.omega * rx;
const ax = b.ax - b.alpha * ry - b.omega ** 2 * rx;   // centripetal + tangential
const ay = b.ay + b.alpha * rx - b.omega ** 2 * ry;
gyro = b.omega;                                       // identical at every point

Explained in Chapter 4: Sensors & Data